On this page
A light-distance practice record separates source-on readings and ambient readings.
Invented practice readings support the fair-test calculation; actual instrument results may differ.Tap image to enlarge ↗

THE BIG IDEAS

  • Subtract a measured ambient level before comparing the lamp contribution.
  • A fixed-direction small-source model predicts inverse-square scaling.
  • A mismatch can reveal the limits of the source or sensor.

Ask a measurable question

How does the reading from one light source change with distance? This activity uses a small cool diffused LED and a teacher-provided light meter. The meter may report illuminance in lux; retain its actual units. If no meter is available, use the invented practice record below for the graph and reasoning task. Human impressions alone cannot test a numerical inverse-square prediction.

Work indoors with adult supervision, stable supports and a clear route about 1.2 m long. Do not use the Sun, a laser or a hot high-power lamp. Keep bright sources out of anyone’s direct line of sight.

Make the comparison repeatable

Fix the LED’s output and orientation. Place the sensor facing it squarely at the same height. Measure from the emitting region to the sensor surface, not between arbitrary equipment edges. Mark distances of 0.4 m, 0.8 m and 1.2 m. Keep nearby people and reflective objects from changing position.

At each distance, take three source-on readings after the display settles. Turn off only the test LED and measure the ambient reading there. Avoid casting a new shadow on the sensor. Restore the lamp without changing its position. Record unstable values rather than choosing the neatest result.

Correct the background before comparing ratios

Find the mean of the three source-on readings at each distance, then subtract that position’s ambient reading. Keep the raw values as well as the corrected ones. If the corrected value is near zero or below zero, the signal is too small or unstable for a reliable ratio.

An ideal small source gives a reading proportional to 1/r² along a fixed direction when the detector responds linearly. Doubling distance predicts one quarter of the corrected reading; tripling it predicts one ninth. A focused beam or extended source at close range may not meet that simple model.

Use an explicitly invented practice record

For a desk analysis, use mean source-on readings of 420, 120 and 64.4 lux at 0.4, 0.8 and 1.2 m. The invented ambient reading is 20 lux at every position. Corrected values are 400, 100 and 44.4 lux. They are teaching examples, not results obtained with your LED or by HONTARA.

Relative to the first value, these are approximately 1, 0.25 and 0.111. As a further check, multiply each corrected value by r²: approximately 64 lux m² each time. Plot distance horizontally and corrected reading vertically, with units.

Explain departures without hiding them

If your own results differ, investigate reflections, sensor angle, source size, changing ambient light, output drift or a saturated meter. A display stuck at its maximum cannot establish the nearby brightness. Your data may reveal an apparatus limitation rather than a failure of the physical model.

Write a conclusion with a range of evidence and one proposed improvement. Keep the conclusion about this source, these distances and this sensor. Do not claim that lux readings establish the lamp’s total radiant power or that eye sensitivity changes linearly with the meter.

PAUSE AND THINK

A mean source-on reading is 120 lux and the ambient level is 20 lux. What should be compared with the lamp-only model?

Explore the answer

The corrected contribution is 120 − 20 = 100 lux. Comparing the raw 120 lux includes background light that does not come from the test LED.

RECORD YOUR OWN EVIDENCE

Your activity sheet

You need: Small cool diffused LED, teacher-provided light meter, ruler or tape, stable supports and pencil. Use the supplied practice data if a meter is unavailable.

Measure source-to-sensor distance at 0.4 m, 0.8 m and 1.2 m. Keep orientation fixed, record three source-on readings and measure the ambient level at each position.

Name or group: Date:

Complete this record as you work
Distance (m)Mean source-on readingAmbient readingCorrected reading
0.4
0.8
1.2
  1. Subtract ambient light and compare the corrected readings with ratios 1, 1/4 and 1/9.

  2. Why could saturation or reflected light make a result depart from the simple model?

Record what happened, including uncertain results. Use the answer guidance in this resource to discuss your explanation.